Walls & Ceilings logo
search
cart
facebook twitter linkedin youtube youtube Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Walls & Ceilings logo
  • NEWS
  • TOPICS
    • Drywall
    • Stucco/EIFS
    • Ceilings
    • Steel Framing
    • Fireproofing
    • Interior Plaster
    • Building Envelope
    • Insulation
    • Technology
    • Interior
    • Exterior
    • Women In Construction
  • COLUMNS
    • Up Front
    • All Things Gypsum
    • Art & Craft of Plastering
    • Stucco Stop
    • Steel Deal
    • Industry Voices
  • PRODUCTS
    • Buzz Guide
  • EVENTS
    • Industry Events
    • Webinars
    • BUILD Expo
  • MEDIA
    • Videos
    • Podcasts
    • Photo Galleries
    • BUILD26 Videos
    • Take our Quiz!
    • Infographics
  • EXCLUSIVE
    • Newsletters
    • Top 50 Contractors
    • Contractor of the Year
    • State of the Industry
    • W&C Store
    • Market Research
    • CEUs
    • Sponsor Insights
    • Custom Content & Marketing Services
  • DIRECTORY
  • EMAGAZINE
    • eMagazine
    • Advertise
    • Archive Issues
  • SIGN UP!
InsulationSteel Framing

Insulating Metal Clad Buildings

Properly installed spray foam insulation can dramatically improve the performance of metal clad buildings, but success depends on careful attention to substrate stability, preparation, and framing details.

By Tom Harris
Insulating Metal Clad Buildings
Images courtesy of Tom Harris PUR Consulting.
February 23, 2026

In a previous article published by Walls & Ceilings, we discussed the importance of carefully determining the required thickness (R-value) of open- or closed-cell spray foam insulation, as well as the potential need for an additional vapor control layer in metal clad buildings. 

In conversations with insulation contractors across the country, several key considerations consistently emerge when installing SPF, whether open or closed cell.  

1. Substrate Stability

There are seven primary metal building panel types, along with multiple variants, including R-panel, PBR panels, standing seam panels, corrugated metal panels, box rib panels, flat metal panels and insulated metal panels.  

Metal thickness (gauge) and yield strength, fastener spacing, fastener type, framing type, and framing material all play a role in determining the structural integrity and stability of individual cladding panels and the overall cladding assembly. SPF contractors are advised to confirm that fastener spacing and fastener types meet the recommendations of the panel or building manufacturer. In retrofit applications, this may require installing additional fasteners prior to applying spray foam insulation. 

Metal thickness and yield strength are the two characteristics most closely related to cladding durability. When closed-cell SPF (ccSPF) is applied to the interior surface of metal panels, it adds a high degree of stiffness to both the panel and the overall wall or roof assembly, increasing wind resistance and load-carrying capacity. Open-cell SPF (ocSPF), by contrast, provides no additional structural strength. 

Contractors should always confirm cladding thickness and fastener spacing before installing SPF. Waves and oil-canning in 28- or 29-gauge metal can often be avoided by limiting the first foam pass to approximately one inch, allowing the foam to fully cure and cool, and then installing the remaining thickness per the manufacturer’s instructions. This approach reduces the maximum heat exposure to the metal during installation. Excessive heat—potentially 150 degrees Fahrenheit or higher—can cause metal expansion, delamination from the foam, oil-canning, and distortion. 

Application of spray polyurethane foam

Photo: PUR Consulting

2. Substrate Preparation

In all cases (especially when applying SPF to metal), proper substrate preparation is essential. Spray foam insulation is designed to fully adhere to the substrate. Machine oils, dirt, dust, rust, and mill scale left from the metal fabrication process can significantly reduce adhesion. The Spray Polyurethane Foam Alliance has published several documents outlining required preparation methods for various substrates, including metal.  

Any areas of delamination must be removed and replaced with fresh foam. In cold-weather applications, it is recommended to apply an initial one-inch pass before installing full-thickness passes. This helps stabilize the metal substrate and reduces stress caused by applying thicker foam layers to cold surfaces. 

In retrofit applications, substrate preparation often includes mechanical abrasion and the application of a primer to enhance bond strength between the foam and the metal. 

In some new construction and retrofit situations, a bond break, such as Tyvek or another membrane, is installed or requested between the metal cladding and spray foam insulation. However, according to SPFA Technical Document 134, “Spray Polyurethane Foam for Metal Buildings,” unstable substrates such as membranes must be removed, and SPF must be applied directly to the metal cladding. In roof applications, vinyl liner insulation systems must also be removed prior to SPF installation. Any material that reduces adhesion between the foam and metal substrate is unsuitable for SPF applications. 

Contractors and applicators are advised to perform pull-adhesion tests whenever foam adhesion is in question. The Air Barrier Association of America (T0002) and the Canadian installation standard CAN/ULC S705.2 provide specific methods and equipment requirements for verifying acceptable adhesion. 

Application of spray polyurethane foam

Photo: PUR Consulting

3. Framing and Transitions

Metal buildings can be framed in many ways—gable, clear-span, or multi-span—using purlins, eave struts, wall girts, wind straps, tension wires, and a wide range of girt and base plate layouts. Additional variables may include insulated or uninsulated slabs, radiant heating systems, and radon barriers. The range of options is extensive. 

Spray foam contractors must ensure that the insulation system addresses air leakage, thermal performance, and code requirements for thermal or ignition barriers between the SPF and the occupied space.  

Air leakage leads to increased energy costs, higher condensation risk, cold spots, and poor indoor air quality. Metal buildings are inherently leaky, and SPF is particularly effective at sealing gaps in structural components, fastener penetrations, and poorly fitted joints. 

Contractors must also be aware of the cladding system, structural framing, and roof design in both retrofit and new construction projects. Certain roof systems, such as standing seam roofs, are designed to allow metal panels to move in response to temperature changes. Applying closed-cell spray foam may restrict this movement and could affect building or roof warranties. It is strongly recommended that contractors consult with the building manufacturer, builder, or owner regarding warranty provisions before installing ccSPF. The Metal Construction Association has published research outlining considerations related to the use of spray foam insulation in metal buildings.  

Metal buildings may appear simple (posts, metal cladding, concrete floors, and a metal roof) but achieving proper building science performance can be more complex than it first appears. Spray foam insulation offers significant advantages over more conventional materials, but like all systems, it must be installed correctly to perform as intended. Education, understanding, and communication remain the cornerstones of a successful project. 

References

  • SPFA Technical Document 134
    SPFA (Spray Polyurethane Foam Association)
  • “Spray Polyurethane Foam Insulation on Interior Surfaces of Metal Panels” 
    Metal Construction Association, September 2023
  • Polyurethane Continuing Education Campus
KEYWORDS: ABAA (Air Barrier Association of America) building science MCA (Metal Construction Association) metal cladding polyurethane R-value SPFA (Spray Polyurethane Foam Alliance) spray foam insulation

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Tom harris
Tom Harris is president of Tom Harris PUR Consulting LLC. He has more than 35 years of polyurethane foam development and deployment experience ranging from Development Chemist, Product and Marketing Management, Business Development and Building Science in Canada and the United States. He can be reached at tom@letstalkpur.com.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • Abercrombie & Fitch

    EIFS in 2026: How Specialty Finishes Are Redefining Exterior Wall Systems

    As building codes, owner expectations, and design demands...
    Stucco/EIFS
    By: Regi Mendoza
  • proper air and vapor control

    From Energy Efficiency to Moisture Management: Why Air and Vapor Control Matter

    How proper air and vapor control within building...
    Building Envelope
    By: Benjamin Meyer AIA, LEED AP
  • Linear Metal Ceiling Beam Baffles

    Top 25 Ceiling Contractors of 2026

    Suspended ceilings demand precision, code compliance and...
    Ceilings
    By: John Wyatt and Tanja Kern
You must login or register in order to post a comment.

Report Abusive Comment

Manage My Account
  • eMagazine Subscription
  • Newsletters
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Walls & Ceilings audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Walls & Ceilings or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • medical professionals moving a patient on a stretcher through the halls of a medical building
    Sponsored byNational Gypsum Company

    What Does High Performance Mean When It Comes To Gypsum Boards?

Popular Stories

Linear Metal Ceiling Beam Baffles

Top 25 Ceiling Contractors of 2026

Wichita Biomedical Campus

Wichita Drywall Worker Dies After Scaffolding Fall

QXO Just Changed the Game-Here's What Contractors Are Asking

QXO Just Changed the Game-Here's What Contractors Are Asking

An interior drywalling work in progress

Boost Profits with AI Scheduling

Events

June 24, 2026

The Bright Side & Benefits of Designing with Integrated Lighting

Credits 1 AIA LU/HSW; 0.1 ICC CEU

This course will explore the pivotal role architects and lighting design play in creating safer, more sustainable spaces. Learn how to avoid common lighting mistakes and make informed decisions that create the best visual environment for occupants. 

January 1, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

See our full library of webinars

View All Submit An Event

Products

2026 National Painting Cost Estimator

2026 National Painting Cost Estimator

See More Products

Related Articles

  • Smith Elementary School in Texas

    A Modern School Using Metal-Clad Panels

    See More
  • Petersen PAC-CLAD Las Vegas Apartments Picture 1

    Metal-Clad Apartments Add Visual Punch to Las Vegas Neighborhood

    See More
  • alan aprt 1

    Modern Metal-Clad Apartments Are Bright Standout in Stucco Country

    See More

Related Products

See More Products
  • barrys.jpg

    Barry's Advanced Construction of Buildings, 4th Edition

  • guyed-steel.gif

    Guyed Steel Stacks

  • 0470872616.jpg

    Sustainable Renovation: Strategies for Commercial Building Systems and Envelope

See More Products

Events

View AllSubmit An Event
  • October 7, 2026

    METALCON International Conference and Exhibition 2026

    METALCON will be held at the Orange County Convention Center this year. As the show marks more than three decades of achievement, it sets the pace for shaping the future with metal through an unbeatable blend of new product exhibits, a nationally recognized education conference, and live-action demos of field techniques. Join contractors, designers, developers, fabricators and suppliers from across the globe who attend this annual event. You’ll meet experts from forward-thinking companies who exhibit their top products and technology, and are eager to share their knowledge with you.
View AllSubmit An Event

Related Directories

  • PAC-CLAD | Petersen

  • Eastern Metal Building Products

×

Connect with the industry’s leading resource for unparalleled insights and education.

Join thousands of industry professionals today. Shouldn’t you know what they know?

JOIN NOW
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletters
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing