Walls & Ceilings logo
search
cart
facebook twitter linkedin youtube youtube Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Walls & Ceilings logo
  • NEWS
  • TOPICS
    • Drywall
    • Stucco/EIFS
    • Ceilings
    • Steel Framing
    • Fireproofing
    • Interior Plaster
    • Building Envelope
    • Insulation
    • Technology
    • Interior
    • Exterior
    • Women In Construction
  • COLUMNS
    • Up Front
    • All Things Gypsum
    • Art & Craft of Plastering
    • Stucco Stop
    • Steel Deal
    • Industry Voices
  • PRODUCTS
    • Buzz Guide
  • EVENTS
    • Industry Events
    • Webinars
    • BUILD Expo
  • MEDIA
    • Videos
    • Podcasts
    • Photo Galleries
    • BUILD26 Videos
    • Take our Quiz!
    • Infographics
  • EXCLUSIVE
    • Newsletters
    • Top 50 Contractors
    • Contractor of the Year
    • State of the Industry
    • W&C Store
    • Market Research
    • CEUs
    • Sponsor Insights
    • Custom Content & Marketing Services
  • DIRECTORY
  • EMAGAZINE
    • eMagazine
    • Advertise
    • Archive Issues
  • SIGN UP!
Building Envelope

Elements of Window Flashings

Four Critical Elements of Window Flashing Design

By Paul Majka
February 2, 2015

The approach to building envelope design has changed drastically over the last 20 years. Historically, the dynamics of structural loads and bearing have had few adjustments. However, the laws of physics factoring in air/moisture movement and drying through wall assemblies have transformed exterior wall design. As a result, design features in today’s wall system include air barriers, vapor retarders, water resistive barriers and flashing systems to address these performance concerns. 

Penetrations through the wall assembly are of the greatest interest and are mission-critical when it comes to integrating these features into wall design. Fenestrations, or windows, are typically the largest penetration through the building envelope. This opening, both by the component’s design and flashing installation, must combine all the features of protection to prevent air movement, moisture and water intrusion. 

There are four critical elements that are fundamental for a window flashing system to provide the building envelope with energy efficiency, durability and longevity. Subsequent consideration as to specific design including climate, wall structure, fenestration characteristics and exterior cladding should always complement these fundamental elements, which include:

  • Sill protection and drainage
  • Head flashing design
  • Air, moisture and thermal protection
  • Product performance and compatibility

Sill Protection and Drainage

When a sill pan is applied (flexible or rigid) to the rough opening there are three performance characteristics the sill pan must provide:

  • Protection: The sill pan must protect the rough sill and all wall components below the window opening from water intrusion. It is also required that the sill pan should prevent water from penetrating the joint between the rough sill and side jamb. In addition, this protection must include resistance against the wicking of water into the rough side jambs.
  • Water collection: A non-sloped sill pan must collect or prevent water from migrating past the interior window frame or beyond the sill flashing termination. This can be achieved by applying a “back-dam” using sealant, closed cell spray foam or an up-turned leg. The up-turned leg can be formed utilizing flexible flashing tape or a rigid sill pan. A sloped sill pan directs water to the exterior of the rough opening and, by design, will prohibit water from interior migration.
  • Drainage: All sill pans must drain water to either a membrane drainage system or “through wall” to the exterior cladding. When a flanged window is fastened to the opening, the bedding sealant used behind the flange should be applied as a discontinuous bead. This would provide voids to allow water to drain to the membrane drainage system.

Head Flashing Design

Head flashing design can be misunderstood depending on cladding type, window protection and procedure. No matter the cladding type, the gap between the head of the window and exterior cladding should not be sealed. This will allow for water to drain and not collect or load above the window. 

Rigid head flashing should always be applied above windows with multiple or mulled units. Rigid head flashing is not required on single window units only. When rigid head flashing is installed bedding sealant should be applied to the bottom and up-turned leg of the flashing. 

In all cases and methods used in ASTM E-2112-07, the water resistive barrier should overlap the head flashing tape and the up-turned leg of the rigid head flashing. Head flashing tape should always overlap and extend 1-inch past side jamb flashing tape on both sides of the window.

A continuous bead of bedding sealant should be applied behind head and side flanges of window. If the window has field installed or non-integral flanges, sealant should be applied to the joint between window and flange connection.

Air, Moisture and Thermal Protection

Redundancies are built into flashing systems. This means that cladding and window sealant, flashing tape and bedding sealant can provide several layers of defense against air infiltration and water intrusion. The final perimeter gap to be sealed is applied from the interior between the rough opening and the window frame. 

Although it may vary, the recommended gap between the rough opening and window frame is a 1/2-inch. Specific window types will have a larger gap between the window and rough sill. If not sealed properly, this perimeter gap will allow air and moisture to pass between interior and exterior conditions. Additionally, the absence of thermal performance can boost thermal conduction. In both examples this can decrease energy efficiency and promote moisture development.

There are a number of methods used to prevent air and moisture movement and promote thermal performance. The use of window and door spray foam is a common application to consider. For example, closed cell polyurethane window and door foam needs to be low expansion, vapor- and water-resistant and air seal large gaps. It also should provide an insulation R-value of 5 to 6 R per inch. 

A few important points to consider with foam application:

  • Professional foam guns provide improved foam application. Many foam guns have adjustable valves to regulate the flow of foam, which can control excessive use and ensure proper application.
  • A minimum depth of 2 inches of foam is recommended in the perimeter gap.
  • If using foam between the windowsill frame and rough sill, never fill the gap to the exterior window frame. A minimum 2-inch space is necessary between the exterior window frame and foam edge. This will encourage water collection and drainage.
  • It is not necessary to fill the gap from the exterior to interior window frame at the head and side jambs.

The performance and compatibility between sealants, flashing tape and foam used for this application are crucial and play an important role for reliability, longevity and reduced risk. 

Product Performance and Compatibility

The performance and compatibility between sealants, flashing tape and foam used for this application are crucial and play an important role in ensuring reliability, longevity and reduced risk. 

Sealant performance and compatibility with air barriers, water resistive barriers and self-adhered flashings are most important to long-term adhesion. The consequences with no sealant or low performing incompatible sealant are similar when it comes to water intrusion. When selecting sealant, self-adhering flashing and window and door foam, these products should conform to AAMA 711 and 713 specifications and testing.

 The design-build team should require product written specifications that provide all performance testing results to confirm the use of each product for the particular flashing application. Notable and trustworthy sealant manufacturers provide all the tools and products needed for a complete window installation system and complement it with a written install warranty.   

KEYWORDS: building envelope design energy efficiency flashing moisture windows

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Paul Majka is applications engineer for the Henkel Corp., where he provides technical support to promote sound building practices using sealants and adhesives for commercial and residential construction. Majka continues to be actively involved in consulting and training architects, engineers, contractors and product suppliers. Throughout his 34 years in the industry, he has worked as a contractor, energy specialist and building diagnostician.

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • Abercrombie & Fitch

    EIFS in 2026: How Specialty Finishes Are Redefining Exterior Wall Systems

    As building codes, owner expectations, and design demands...
    Stucco/EIFS
    By: Regi Mendoza
  • proper air and vapor control

    From Energy Efficiency to Moisture Management: Why Air and Vapor Control Matter

    How proper air and vapor control within building...
    Building Envelope
    By: Benjamin Meyer AIA, LEED AP
  • Linear Metal Ceiling Beam Baffles

    Top 25 Ceiling Contractors of 2026

    Suspended ceilings demand precision, code compliance and...
    Ceilings
    By: John Wyatt and Tanja Kern
You must login or register in order to post a comment.

Report Abusive Comment

Manage My Account
  • eMagazine Subscription
  • Newsletters
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Walls & Ceilings audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Walls & Ceilings or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • medical professionals moving a patient on a stretcher through the halls of a medical building
    Sponsored byNational Gypsum Company

    What Does High Performance Mean When It Comes To Gypsum Boards?

Popular Stories

Linear Metal Ceiling Beam Baffles

Top 25 Ceiling Contractors of 2026

Wichita Biomedical Campus

Wichita Drywall Worker Dies After Scaffolding Fall

QXO Just Changed the Game-Here's What Contractors Are Asking

QXO Just Changed the Game-Here's What Contractors Are Asking

An interior drywalling work in progress

Boost Profits with AI Scheduling

Events

June 24, 2026

The Bright Side & Benefits of Designing with Integrated Lighting

Credits 1 AIA LU/HSW; 0.1 ICC CEU

This course will explore the pivotal role architects and lighting design play in creating safer, more sustainable spaces. Learn how to avoid common lighting mistakes and make informed decisions that create the best visual environment for occupants. 

January 1, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

See our full library of webinars

View All Submit An Event

Products

2026 National Painting Cost Estimator

2026 National Painting Cost Estimator

See More Products

Related Articles

  • Water Conservation 101: The Elements of Facility Design

    See More
  • Window of Opportunity

    See More
  • A building featuring a stucco exterior

    Head Flashings at Window and Door Openings

    See More

Related Products

See More Products
  • barrys.jpg

    Barry's Advanced Construction of Buildings, 4th Edition

  • bim 3e.jpg

    BIM Handbook: A Guide to Building Information Modeling for Owners, Designers, Engineers, Contractors, and Facility Managers, 3rd Edition

  • 2021 ibc.jpeg

    2021 International Building Code® Illustrated Handbook

See More Products

Events

View AllSubmit An Event
  • June 24, 2026

    The Bright Side & Benefits of Designing with Integrated Lighting

    Credits 1 AIA LU/HSW; 0.1 ICC CEU This course will explore the pivotal role architects and lighting design play in creating safer, more sustainable spaces. Learn how to avoid common lighting mistakes and make informed decisions that create the best visual environment for occupants. 
View AllSubmit An Event

Related Directories

  • MFM Building Products

    Waterproofing Membranes: MFM manufactures a full line of self-adhering waterproofing membranes including window and door flashing tapes, construction, joint and roofing membranes.
×

Connect with the industry’s leading resource for unparalleled insights and education.

Join thousands of industry professionals today. Shouldn’t you know what they know?

JOIN NOW
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletters
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing